SDS-97D Series   Sensor/Transmitters for a Wide Range of Toxic Gases, Hydrogen and Oxygen
Enmet

You are Here: Home » Stationary/Fixed/Continuous Monitors » SDS 97D

Enmet spacer

Navigate this page:

carrot

Specifications

carrot

Ordering Information

carrot

Contact ENMET

carrot

Download Printable Version for this Instrument

carrot

Go To Product Literature

Enmet spacer
 
gas selector
 
Enmet spacer

EN-Series

Sensor / Transmitters

Without Digital Display Are Also Available.

Enmet spacer
 
Enmet spacer

Calibration Equipment, Replacement Parts and Accessories are available.
Call us for More Information.

Enmet spacer

SDS-97D Series

Sensor/Transmitters for a Wide Range of Toxic Gases, Hydrogen and Oxygen

 

  • Non-intrusive push button calibration

  • Excellent chemical selectivity

  • 4-20 mA output, 24 Vdc loop powered

  • One-person calibration

  • Digital display

  • Electrochemical sensors

  • RFI/EMI resistant

  • Optional Precalibrated Sensor Exchange

 

SDS-97D Series Sensor/Transmitters utilize electrochemical type cells to detect the target gas. These cells consist of electrodes, electrolyte and an air/liquid separation barrier. Gas molecules enter the cell and, as a result of an oxidation/reduction reaction, generate an electrical current proportional to the gas concentration. This current is measured, conditioned, converted to the gas concentration, digitally displayed and transmitted as a 4-20 mA output signal. ENMET offers a variety of multi-channel controller/ alarm modules that provide the 24 Vdc loop power and receive the 4-20 mA signal from the sensor/transmitters. These sensor/transmitters can also be connected to various computer based instrumentation, PLCs, etc.

 

The use of a gas sampler generally improves monitoring performance for all gases. It is particularly recommended for Cl2, HCl, AsH3, and it is required for monitoring HF and O3.

 

The standard SDS-97D Sensor/Transmitters (P/N 10022-XXXX) incorporate an external push button for non-intrusive zeroing and gas calibration of the device. An optional version of the SDS-97D Sensor/Transmitters (P/N 10021-XXXX) feature a communication port and hand-held programming module (P/N 10021-001) which facilitate the elimination of the need for on-site gas calibration. Contact ENMET for details regarding the Precalibrated Sensor Exchange Program.

Enmet spacer

Specifications, SDS-97D

Size, approx:

4.75 w x 2.60 h x 1.85 d inches
(12 x 6.6 x 4.7 cm)

 

Weight:

1 lb. (454 g)

 

Enclosure:

Painted (polyurethane enamel) aluminum

 

Sensor:

Electrochemical cell, disposable, plug-in type

 

Display:

8 character, dot matrix LCD with backlight

 

Sensor Location from Controller:

Up to 2,000 feet (600 meters). Consult factory for greater distance.

 

 

 

Cable:

3-wire, shielded

Max. loop resistance: 300 ohms @ 24 Vdc

Typical installation wire: 20 AWG (0.5 mm2)

 

Voltage:

24 Vdc (10-30 Vdc), loop powered

 

Current Draw:

45 mA maximum

 

Output:

4-20 mA

 

Temperature Range:

-4° to 104° F (-20° to 40° C)

 

Humidity Range:

5 to 90% rH, non-condensing

 

Pressure Range:

Atmospheric ±10%

spacer

Gas Sampler Option

 

The use of a gas sampler generally improves monitoring performance for all gases. It is particularly recommended for Cl2, HCl, AsH3, and it is required for monitoring HF and O3.

Gas Sampler

Model GS-24-DF, P/N 04565-311 Gas Sampler, 24 Vdc with digital flow display. Shown here with SDS-97D Series Sensor/Transmitter.

 

 

 

 

 

back to top

 

Enmet spacer

Ordering Information

Enmet spacer
Enmet spacer

Gas (1)

Model

Range

LDL (4)

Controller Alarms, PPM (5)

Ammonia, NH3

SDS-2400-97D

100 ppm

6 ppm

25, 50, 75

Arsine, AsH3 (2)

SDS-4001-97D

0.50 ppm

0.04 ppm

0.05, 0.1, 0.4

Carbon monoxide, CO

SDS-1200-97D

500 ppm

4 ppm

35, 50, 200

Chlorine, Cl2 (2)

SDS-0100-97D

10.0 ppm

0.4 ppm

0.5, 1, 5

Ethylene oxide, ETO

SDS-5200-97D

10.0 ppm

1.2 ppm

3, 5, 9

Hydrogen, H2

SDS-1500-97D

2000 ppm

24 ppm

200, 500, 1000

Hydrogen chloride, HCl (2)

SDS-0400-97D

30.0 ppm

0.8 ppm

5, 10, 20

Hydrogen fluoride, HF (3)

SDS-0700-97D

10.0 ppm

0.8 ppm

3, 6, 9

Hydrogen sulfide, H2S

SDS-0200-97D

100 ppm

4 ppm

10, 20, 50

Nitric oxide, NO

SDS-1750-97D

100 ppm

4 ppm

25, 50, 75

Nitrogen dioxide, N02

SDS-1700-97D

30.0 ppm

1.2 ppm

3, 5, 10

Oxygen, 02

SDS-1100-97D

30.0%V

0.2%V

17, 19.5, 23.5%V

Ozone, 03 (3)

SDS-0800-97D

1.00 ppm

0.04 ppm

0.1, 0.5, 0.75

Silane, SiH4

SDS-4003-97D

30.0 ppm

3.2 ppm

5, 10, 20

Sulfur dioxide, SO2

SDS-0500-97D

30.0 ppm

0.8 ppm

2, 5, 10

Enmet spacer
Enmet spacer

(1) Consult ENMET for gases not on this list
(2) For best performance, it is recommended that a sample draw system be used for monitoring these gases
(3) Monitoring of these gases requires the use of a sample draw system
(4) Lower Detectable Limit calculated from baseline noise level, thermal drift and interference data used to derive zero point deviation estimates
(5) Standard factory alarm points for ENMET controllers when used with these SDS-97D Series Sensor/Transmitters.

back to top

Enmet
Ask Us a Question GSA Contract GS-24F-3035G, GS-24F-0001K
GSA Contract GS-24F-3035G, GS-24F-0001K

Home | Products: Overview | Stationary Fixed Continuous Monitors | Portable Multigas Monitors

Personal Single Gas Monitors | Respiratory Compressed Air Monitors

Support & Documentation: Overview | Technical Information | Instrument Manuals

Corporate Info: Contact Info | Company Profile | Safety Seminars

 

P.O. Box 979, Ann Arbor, Michigan 48106-0979   Phone (734) 761-1270, FAX (734) 761-3220

© 2006-2007 Enmet Corporation. All Rights Reserved. (ah)

Developed by Miller Media Inc.