Creative Gas Detection Solutions

CP-60 Hazardous Gas Detection Controller

CP-60 Hazardous Gas Detection Controller

Home » Products » Controllers » CP-60 Hazardous Gas Detection Controller

CP-60 Hazardous Gas Detection Controller

1-3 Channel Wall-Mount Hazardous Gas Monitor Controller

CP-60 is a 1, 2, or 3 channel wall mount controller designed for monitoring up to three 4-20 mA inputs from remote gas sensor/transmitters or similar devices. The instrument provides 24 VDC power, audible/visual alarms, alarm relays.

  • User-programmable alarms and high capacity relays
  • Up to three 4-20 mA inputs & outputs
  • 100-240 VAC, 12 VDC power options
  • High-integrity thermoplastic enclosure
  • RS-485 digital communication capability
  • Designed for 12 VDC battery backup

Display: High-contrast dot matrix LCD with backlight.

Up to 3 sections (1 per channel)

Each section: 1 line, 8 character, 4 digit, 3 alpha, 1 space

Name: 3 letter (A-Z), factory programmed

Range: 0.00 to 9999, factory programmed

Inputs, up to three: 4-20 mA, 2-wire, 3-wire or 4-wire (consult factory)

Loop Power: +24 VDC provided

Alarm Levels: 2 user-programmable alarms per channel

Audible Alarm: 95 dB at 60 cm (24 inches), factory set to activate at

Alarm 1, user adjustable

Visual Indicators: Blinking red LED, Alarm 1, 1 per channel

Solid red LED, common Alarm 2

Red Fault LED

Green Power LED

Temperature Range: 5° to 104°F (-15° to +40°C)

Outputs: Relays: 6 Form C, 10A SPDT contacts, 5 alarms and 1 fault

Analog: 4-20 mA

Digital: RS-485 Modbus

Connections:  Supplied with strain reliefs for 0.20 to 0.35 inch diameter cable for power and 4-20 mA inputs

Enclosure:  Thermoplastic box with clear, hinged front cover, designed for NEMA 12 and 4X.

Size:  10.5 H x 8.5 W x 5.8 D inches (27 x 22 x 15 cm)

Weight:  8 lbs. (3.6 kg)

  • 1-3 Butadiene (C4H6)
  • 2-Butanone (MEK) (C4H80)
  • Acetaldehyde (CH3CHO)
  • Acetone (CH3)2CO
  • Acetonitrile (CH3CN)
  • Acetylene (C2H2)
  • Ammonia (NH3)
  • Arsine (AsH3)
  • Benzene (C6H6)
  • Boron trichloride (BC13)
  • Bromine (Br2)
  • Butane (C4H10)
  • Carbon Dioxide (CO2)
  • Carbon monoxide (CO)
  • Chlorine (Cl2)
  • Chlorine dioxide (CLO2)
  • Combustible Gas
  • Disilane (Si2H6)
  • Ethane (C2H6)
  • Ethyl alcohol (C2H5OH)
  • Ethylene (C2H4)
  • Ethylene oxide (ETO) (C2H4O)
  • Fluorine (F2)
  • Gasoline
  • Heptane (C7H16)
  • Hexane (C6H14)
  • Hydrazine (N2H4)
  • Hydrocarbons
  • Hydrogen (H2)
  • Hydrogen bromide (HBr)
  • Hydrogen chloride (HCl)
  • Hydrogen cyanide (HCN)
  • Hydrogen fluoride (HF)
  • Hydrogen sulfide (H2S)
  • Isobutane (C4H10)
  • Isobutylene (C4H8)
  • Isopropanol (CH3) CHOH
  • Isopropyl alcohol (IPA) (C3H8O)
  • Jet Fuel (JP8)
  • Kerosene
  • Methane (CH4)
  • Methanol (CH3OH)
  • Methyl alcohol (CH3OH)
  • Methyl chloride (CH3Cl)
  • Methyl ethyl ketone (MEK) (C4H8O)
  • Meythlene chloride (CH2Cl2)
  • Natural Gas
  • Nitric oxide (NO)
  • Nitrogen dioxide (NO2)
  • Octane (C8H18)
  • Organic solvents
  • Oxygen (O2)
  • Ozone (O3)
  • Pentane (C5H12)
  • Phosphine (PH3)
  • Propane (C3H8)
  • Propylene (C3H6)
  • Propylene oxide (C3H6O)
  • Silane (SiH4)
  • Solvents
  • Styrene (C8H8)
  • Sulfur dioxide (SO2)
  • Toluene (C7H8)
  • Trichloroethylene (C2HCl3)
  • Vinyl chloride aka Chloroethene (VCM) (C2H3Cl)
  • Volatile Organic Compounds (VOCs)
  • Xylene (C8H10)

Calibration Equipment:

Calibration equipment for the CP-60 controller is dependent upon the type of sensor/transmitter included with the controller. Calibration equipment should be purchased according to the sensor/transmitter calibration equipment requirements.  Contact ENMET with model numbers and serial numbers of both the CP-60 and the sensor/transmitters associated with the controller when inquiring about calibration equipment.

System Options and Accessories

Several accessories can be purchased with the CP-60 controller and corresponding sensor/transmitter. Listed are some of the more common items purchased:

Part No.                 Description

04546-004            Splash Guard for EX Series: 5120, 5155, 5165, 5175 & 5185 Sensor/Transmitters

04546-005            Splash Guard for EX-5100 Sensor/Transmitters

04546-006            Splash Guard for EX-5150-MOS Sensor/Transmitters

04546-007            Splash Guard for EX-5130 Sensor/Transmitters

04546-010            Splash Guard for EX-6100 Sensor/Transmitters

04566-004            Battery Backup, 12 VDC, 24 amp/hour

62020-002            Strobe Light, Red, 12-72 VDC

62020-003            Strobe Light, Red, 120 VAC

NOTE: Other system options available, consult factory for more information.

To place an order, please contact our experienced and professional customer service team:

PHONE: 734-761-1270

If you cannot find what you need or require a custom part, simply call and speak to one of our knowledgeable gas monitoring experts. They will be able to walk you through the ordering process quickly and professionally.

Instrument                                                              Part No.

CP-60, 1-CHANNEL CONTROLLER                      04651-001

CP-60, 2-CHANNEL CONTROLLER                      04651-002

CP-60, 3-CHANNEL CONTROLLER                      04651-003

Sign up for our newsletter?

Stay up to date with our happenings, developments and new products!

Leave details
Newsletter