Enmet Home Enmet Products Enmet Support and Documentation Enmet Corporate Info
Enmet
TARGET   Gas Detector

You are Here: Home » Portable Multigas Monitors » TARGET

Navigate this page:

carrot

Specifications

carrot

Gases Detected

carrot

Contact ENMET

carrot

Download Printable Version for this Instrument

carrot

Go To Product Literature

Enmet spacer
 
gas selector
 
Enmet spacer

Standard Sensor Configuration for typical confined space entry:

CO, H2S, LEL, MOS, O2

Enmet spacer
 
Sensor Programming currently available for: Cl2, SO2, NO2, HCl, NH3, and O3. Consult factory for other gases.
Enmet spacer
 
Enmet spacer

TARGET with a combustible sensor is preprogrammed for these gases

(0-100% LEL):
Methane, Propane, Butane, Pentane, Hexane, Hydrogen, Ethane, Benzene, Toluene, and Xylene

Enmet spacer
 
Enmet spacer
Calibration Equipment, Replacement Parts and Accessories are available. Call us for More Information.
Enmet spacer

TARGET

Gas Detector

 

  • Broad-range toxic sensor available

  • Simultaneous display of all sensor readings

  • 10 pre - programmed combustible response options

  • User programmable for: Location, person, date, time

  • Datalogging/STEL/TWA standard

  • Peak Hold

  • Remote display capability

  • Push button auto zero
    and calibration

  • Flexible battery configurations

  • Extended battery life

  • Optional internal motorized sample pump

  • Designed to minimize RFI

  • Rugged metal enclosure

  • Dual-rate battery charger

  • Intrinsically safe design

  • Calibration/recalibration dating on display

 

Enmet Corporation introduced the concept of a hand-held, multi-function gas detector for confined space monitoring back in 1974. Since then, Enmet has continued to pioneer the development of gas detectors for monitoring oxygen deficiency, as well as toxic and combustible gases.

 

TARGET is based upon user input. This instrument provides durable packaging Enmet is noted for, up to five sensors including broad - range toxic, peak hold, latching alarms, and multiple alarm levels.

 

TARGET is the correct size and shape —not too large, not too small, yet lightweight and durable. Options include internal motorized sample pump, flexible battery configurations, and a wide selection of toxic gas sensors.

Enmet spacer

Gases Detected

Enmet spacer
Enmet spacer

Gases Detected

Range

Alarm 1

Alarm 2

Ammonia, NH3

99 ppm

25 ppm

50 ppm

BroadRange BRH

200 ppm

100 ppm

150 ppm

Carbon monoxide, CO

500 ppm

35 ppm

200 ppm

Chlorine, Cl2

9.9 ppm

0.5 ppm

5.0 ppm

Combustibles

99% LEL

10% LEL

50% LEL

Hydrogen chloride, HCl

20.0 ppm

5.0 ppm

10.0 ppm

Hydrogen sulfide, H2S

200 ppm

10 ppm

20 ppm

Ozone, O3

3.00 ppm

0.10 ppm

0.30 ppm

Oxygen, O2

30 % by vol.

19.5 %

23.5 %

Nitrogen dioxide, NO2

30.0 ppm

1.0 ppm

5.0 ppm

Sulfur dioxide, SO2

30.0 ppm

2.0 ppm

10.0 ppm

enmet spacer
enmet spacer

 

TARGET   Gas Detector

 

 

 

back to top

Enmet spacer

Specifications

SENSORS

Combustible - Catalytic

Oxygen & Toxic - Electrochemical

Broad-range Hydrocarbons -

Metallic Oxide Semiconductor (MOS)

 

Sampling Method

Diffusion or optional internal pump

 

Power Source

Nickel metal hydride battery pack

or optional alkaline

 

Battery Life

Up to 16 hours

 

Dimensions

6 x 4.5 x 1.7 inches

(150 x 115 x 45 mm)

 

Weight

32 ounces (900 grams)

 

Operating Temperature

5 to 122 ° F
(-15 to 50 ° C) Continuous

 

Humidity

5 - 99%, non-condensing

 

Display

Dot-matrix liquid crystal (LCD) with backlight, 4 lines 20 characters

back to top